Responding to a Fecal Occult Blood (FOBT/FIT) Deficiency on the CMS-2567
A strong plan of correction for a FOBT/FIT finding names the fix, shows a look-back for affected patient results, changes the system that failed, assigns monitoring and gives a completion date, with the FOBT/FIT records that prove it attached.
What a FOBT/FIT plan of correction should cover
CMS returns plans that only promise to do better. Plans of correction generally need to explain:
- The fix: what was corrected for FOBT/FIT and when.
- The look-back: how you found other FOBT/FIT results or patients that may have been affected, and what you did about them.
- The system change: the procedure, training or software change that keeps it from happening again.
- The monitor: who checks it, how often, and where it is reported (for example to the laboratory director or QA meeting).
- The date: a realistic completion date for each item.
Evidence to attach for FOBT/FIT
- Daily FOBT/FIT QC records, Levey-Jennings charts, corrective action log, control lot ranges
- Six-month FOBT/FIT calibration verification and reportable range data with director review
- Twice-yearly FOBT/FIT accuracy checks (external PT, split samples or reference material) with acceptance criteria
- FOBT/FIT verification study: accuracy, precision, reportable range, reference interval check, director sign-off
- Critical value list, call log with read-back, report format showing FOBT/FIT reference intervals
- Training and competency records for everyone who runs FOBT/FIT
FOBT/FIT PT and accuracy
Not listed in Subpart I: no required PT, but accuracy must be verified at least twice a year (42 CFR 493.1236(c)). If the finding involves PT, include the investigation of each unacceptable result and the remedial action taken; routine chemistry rules require that documentation be kept for two years (42 CFR 493.841).
Common root causes behind FOBT/FIT findings
- Follow sample collection and storage instructions exactly; delays reduce sensitivity for FIT.
- Developer and card QC must follow the manufacturer's instructions.
- Procedures that do not match what staff actually do.
- No second-level review of QC and calibration verification records.
Related tests
- Hemoglobin (full guide)
- Complete Blood Count (CBC) (full guide)
- H. pylori Testing (Antigen, Breath or Antibody) (full guide)
Full guide: Fecal Occult Blood (FOBT/FIT) testing in the clinical lab: CLIA, PT and QC requirements on soundlabconsult.com, part of the Laboratory Test Compliance Library.
Need help writing your plan of correction?
Sound Lab Consultants helps laboratory directors work through root causes and write plans of correction and allegations of compliance that answer each D-tag.
Related guides on soundlabconsult.com:
Frequently asked questions
How do I write a plan of correction for a FOBT/FIT deficiency?
State the correction, the look-back for affected FOBT/FIT results, the system change, the monitoring and a completion date, and attach the supporting records.
What records support a FOBT/FIT plan of correction?
Daily FOBT/FIT QC records, Levey-Jennings charts, corrective action log, control lot ranges; Six-month FOBT/FIT calibration verification and reportable range data with director review; Twice-yearly FOBT/FIT accuracy checks (external PT, split samples or reference material) with acceptance criteria.
Where is the plan of correction written?
On Form CMS-2567, the Statement of Deficiencies and Plan of Correction, or in the format your state agency or accrediting organization specifies.
Sources
- Form CMS-2567, Statement of Deficiencies and Plan of Correction
- CMS State Operations Manual, Chapter 6 (Special Procedures for Laboratories)
- 42 CFR 493.1256, Control procedures
- 42 CFR 493.1255, Calibration and calibration verification
- 42 CFR 493 Subpart H, Participation in Proficiency Testing
- CMS State Operations Manual, Appendix C (Laboratories)